- Home
- About Us
- Products & Services
- Absorbents & Spill Kits
- Drain Protection
- Drum Storage and Sump Pallets
- Flexible Liquid Storage Tanks and Bunds
- Marine Spill Containment
- Spill & Flood Barrier Containment
- Pollution Monitoring Equipment
- Spill Training Courses
- Services and Contracting
- Free Site Assessment
- Free bund compliance survey
- Bund Maintenance and Relining Services
- Separator Alarm Installation and Servicing
- Separator Servicing
- Tank Supply, Installation and Maintenance
- 24 Hour Spill and Flood Response
- Pollution Incident Response Planning
- Bioremediation
- Spill Impact Assessment
- Drainage surveys
- Flood surveys
- Laboratory services
- PPE, Signs & Safety Products
- Inflatable tents
- Railway Industry
- Refractory
- Equipment Hire
- Offers
- Ensure compliance to regulations with our free site survey
- Save up to 50% on our Biocat Recycling Centre Starter Kit for a limited time only
- Website launch offer - ecomat pads Buy 1 Get 1 Free
- Free bund compliance survey in line with Oil Storage Regulations 2001
- Spill Training from £140.00 per person
- Downloads
- Case Studies
- Fuel distribution company meets legislation and reduce waste management costs
- Generator supplier needs provision for protecting drainage systems
- Free site survey and correct location of spill kits prevent diesel flowing into a storm drain
- Aviation fuel supplier requires 24 hour security drainage containment system
- Need for a streamlined and cost effective ordering method for regular absorbent orders
- Distributor requires lining of an indoor storage area to prevent oil leaking through concrete
- Aviation company requires bulk fuel bunded storage area
- Food manufacturer needs bund relined to stop oil leaking through concrete bund wall
- Oil distribution company needs to protect watercourse from oil spills
- Installation of debris booms prevents Xenospheres getting into local rivers
- Boom installation at power station captures debris entering water intakes
- Remediaton of clients premises to remove fuel spill stains
- DrainTector
- Legislation
- Contact Us
Separator Servicing
The Pollution Prevention Guidelines - Use and design of oil separators in surface water drainage systems (PPG3) state:
“To prevent pollution and minimise your costs, you need to manage your separator effectively. To make this easy, all parts of the separator that have to be regularly maintained must be accessible at all times. Every six months, or in accordance with manufacturer’s instructions, experienced personnel should:
- Physically inspect the integrity of the separator and all mechanical parts
- Assess the depth of accumulated oil and silt
- Service all electrical equipment such as alarms and separator management systems
- Check the condition of any coalescing device and replace it if necessary
- Some heavily used or high-risk sites might require more frequent inspections.”
DARCY SEPARATOR SERVICE PLAN
It is essential that separators are regularly maintained, even if an oil level alarm has been installed. You should not wait until the alarm is activated before a separator is serviced. The system requires regular maintenance, calibration, and servicing by a competent technician, to reduce the risk of a pollution incident.
Darcy Spillcare Manufacture has devised a comprehensive range of separator services to ensure your units are maintained and operational for the purpose for which they were installed.
Our services are based on the requirements detailed in the maintenance sections of the Environment Agency's PPG3 document and the European Standard EN858-2 (copies available upon request).
All of our services are carried out by experienced engineers, who will provide you with an appropriate maintenance service record sheet, with a log register for each separator.
ONE YEAR SERVICE CONTRACT - SEPARATOR
The 1-year service Contract consists of 2-service visits per year in which we carry out the following tasks:
- Measure light liquids and solid levels and detail findings in a service log (if levels are unacceptable site personnel are immediately informed
- Revalidate Separator monitor and clean probe,
- Carefully clean all wires to Probes & Float switch making sure not to damage the wires insulation covering (Damage to insulation could result in ‘electrical tracking’ causing miss-operation). If the wires outer insulation is damaged then clean area, allow to dry and insulate using a Conformal coating spray (Non-conductive lacquer).
- Make sure all probes are straight and will not contact the inside of tubular cover when re-fitted.
- Revalidate Automatic closure Device.
- Organise cleaning and emptying of tank (if required) at agreed rates
- Jet wash down coalescing filter (if applicable)
- If required, replace coalescing filter at agreed rates
- Dispose of used filter at agreed rates
- Identify any components that need to be repaired or replaced.
Please note this service is currently available throughout the UK only.